The following control types are available for VECTOR drives:
● U/f control with linear characteristic
● U/f control with linear characteristic and FCC
● U/f control with parabolic characteristic
● U/f control with parameterizable characteristic
● U/f control with linear characteristic and ECO
● U/f control for drive requiring a precise frequency (e.g. textiles)
● U/f control for drive requiring a precise frequency and FCC
● U/f control with parabolic characteristic and ECO
● Operation with braking resistor
● I/f control with fixed current
● U/f control with independent voltage setpoint
● Speed control (without encoder)
● Speed control (with encoder)
● Torque control (without encoder)
● Torque control (with encoder)
Precondition
● You have completely specified and configured the motor used in the device configuration
of the drive axis.
Note
This basic parameterization cannot be performed without having completed this full
configuration.
Selecting the control type
1. Select one of the control types listed above (p1300).
The screen form is structured according to the selected control type.
Note
If a "U/f control xxx" version is selected as the control type, other setting screen forms in
the secondary navigation of the drive axis, such as current controller or current setpoint
filter, are automatically hidden.
4.8.4.4

Limits

Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
"Drive axis > Parameters > Basic parameterization > Limits"
4.8 Basic parameterization of the drive objects
Commissioning
191