Displaying The Trace Recording - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

● The trace configuration in the drive is displayed in the working area (see Chapter
"Creating or calling a trace (Page 269)").
● The icon
Activating the trace recording
Proceed as follows to activate the trace recording in the drive:
1. Click on icon
The trace is activated in the drive and starts the recording corresponding to the
configured trigger condition.
The current status of the recording is displayed in the status display of the trace.
Note
When a recording is restarted, the previously recorded values are lost.
To save the values that have been recorded, save the measurement in the project (see
Chapter "Saving measurements in the project (Page 276)"), before you reactivate the
recording.
Deactivating the trace recording
Proceed as follows to exit the activated trace recording in the drive:
1. Click on icon
The trace is deactivated in the drive.
The status display of the trace changes to "Inactive".
5.3.2.6

Displaying the trace recording

Preconditions
● There is an online connection to the drive unit.
● A recorded trace is saved in the drive unit.
Or:
● A measurement is in the "Measurements" system folder.
Procedure
To display the recording, proceed as follows:
1. Select a trace in the drive.
2. Double-click the selected trace.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
for monitoring the displayed trace is enabled.
.
.
Diagnostics
5.3 Diagnostics via Startdrive
275