Connecting The Motor Holding Brake; Interface Description (Converter Side); Interface Description (Motor Side) - Siemens SINAMICS S200 Operating Instructions Manual

Pulse train servo drive system
Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

6.5.3

Connecting the motor holding brake

6.5.3.1

Interface description (converter side)

Overview
The motor holding brake prevents the moving load from unexpected motions (for example,
falling under the influence of gravity) when the servo drive system is deactivated.
The holding brake is activated once the motor power is cut off. Use the holding brake only
when the motor is at a standstill. Do not use the holding brake to stop the load in motion.
Description
S200 PTI
S200 PTI connects to the motor holding brake via the interface X108.
Table 6-5
X108
S200 Basic PTI
S200 Basic PTI does not have a designated interface for connecting to the holding brake. To
use the holding brake, connect a third-party device via a digital output at the interface X132
and configure the holding brake function as follows:
• Set p1215 to 3.
• Interconnect the digital output signal to r0899.12.
6.5.3.2

Interface description (motor side)

Overview
The motor holding brake interface on the motor is used to connect the built-in holding brake to
the converter.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Interface X108
Terminal
Designation
1
BRN
2
BRP
6.5 Connecting the motor
Technical specifications
Motor holding brake, negative
Motor holding brake, positive
Connecting