Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
5.4
Manual Bypass (for the optional AD-17) CD Registration
Adjustment
✽ Di2011 Only
NOTE
• This adjustment is to be made when the PH Unit has been replaced.
<Adjustment Procedure>
1. Load the Paper Feed Tray/1 with A4 crosswise paper.
2. Enter Function of the Service mode.
3. Select "Print Test Pattern" and then "Test Pattern1." Then, press the Start key.
✽ This will produce a test pattern.
4. Place the test pattern produced on the Original Glass.
5. Load A4 crosswise paper in the Manual Bypass and make a test copy.
A
6. Check width A on the copy of the test pattern.
If width A falls outside the specified range, per-
form the following steps to make an adjustment.
Specifications
20 ± 2.0 mm
4686D504AA
7. Open the Right Door.
8. Remove two screws and the Manual Bypass
Cover.
4532U028AA
2-60
ADJUSTING/SETTING