Fuser Temp. Ad (Ohp) - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

ADJUSTING/SETTING
(8)

FUSER TEMP. Ad (OHP)

Purpose
To set the fusing temperature when OHP trans-
parencies are used.
✽ When fusing failure occurs
<Temperature table for adjusting fusing temperature for OHP transparencies>
For Di1611
Setting value
1
0 (default value)
-1
For Di2011
Setting value
1
0 (default value)
-1
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Paper width
CD
251 mm or more
250 mm or less
251 mm or more
250 mm or less
251 mm or more
250 mm or less
Mode selected in Service's Choice
Mode 1
Heater Lamp temperature (main/sub)
2-25
Setting Details/Precautions
• The default setting is "0."
Setting range: -1 to +1
Mode selected in Service's Choice
Mode 1
Heater Lamp temperature
180 ° C
165 ° C
180 ° C
155 ° C
170 ° C
145 ° C
Mode 3
175 ° C
165 ° C
155 ° C
Mode 3
175 ° C
165 ° C
165 ° C
155 ° C
155 ° C
145 ° C