5. Mechanical adjustment
5.
Mechanical adjustment
5.1
Registration adjustment
NOTE
• Make this adjustment after any of the following procedures has been performed.
When the printed image deviates in the CD direction.
1. Remove the tray.
[1]
[1]
14
2. Loosen two screws [1].
4537F3C501DA
[3]
3. Loosen two screws [1].
4. Watching the graduations [2] on the
adjusting plate, move the edge guide
plate [3] as necessary.
Adjustment range: ± 2.0 mm
5. Tighten the four screws that have
been loosened, and mount the tray.
[1]
[2]
4537F3C502DA