Mechanical Adjustment
2.
Mechanical Adjustment
2.1
Registration adjustment
This adjustment must be made if:
• The printed image deviates in the CD direction.
[1]
[2]
Lower Feeder Unit Field Service Ver. 2.0 April 2005
1. Remove the tray.
2. Loosen two screws [1].
4537fs3501c0
3. Loosen two screws [2].
[4]
4. Watching the graduations [3] on the
adjusting plate, move the Edge
Guide Plate [4] as necessary.
5. Tighten the four screws that have
been loosened and mount the tray.
[2]
[3]
4537fs3502c0
3-2
Adjustment range: ± 2.0 mm