Konica Minolta Di1611 Service Manual page 166

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Malfunc-
tion
Malfunction Name
Code
C0500
Warm-up failure
Warm-up failure
(for the model hav-
ing two Fusing
C0500
Roller Heater
Lamps)
Di2011 Only
Warm-up failure 2
(for the model hav-
ing two Fusing
C0501
Roller Heater
Lamps)
Di2011 Only
Fusing failure
C0510
(abnormally low
fusing temperature)
Fusing failure
(abnormally low
fusing temperature
C0511
2)
Di2011 Only
Fusing failure
C0520
(abnormally high
fusing temperature)
Detection Timing
• The surface temperature of the Fusing Roller does not
reach a given level even after the lapse of a given period
of time during a warm-up cycle.
From room temperature to 100°C:
From 100°C to 140°C:
From 140°C to the completion of
the warm-up cycle:
• The Fusing Roller Thermistor does not detect a prede-
termined temperature within 30 sec. after a warm-up
cycle has been started and thus the warm-up cycle is
not completed.
• The surface temperature of the Fusing Roller does not
reach a given level even after the lapse of a given period
of time during a warm-up cycle.
From room temperature to 60°C:
From 60°C to 100°C:
From 100°C to 130°C:
From 130°C to 155°C:
• The Fusing Roller Sub Thermistor does not detect a
predetermined temperature within 30 sec. after a warm-
up cycle has been started and thus the warm-up cycle is
not completed.
• The surface temperature of the Fusing Roller does not
reach a given level even after the lapse of a given period
of time during a warm-up cycle.
From room temperature to 60°C:
From 60°C to 100°C:
From 100°C to 130°C:
From 130°C to 155°C:
• The temperature detected by the Fusing Roller Ther-
mistor remains lower than 120°C (105°C for the model
having two Fusing Roller Heater Lamps) for a given
period of time during the standby state.
• The temperature detected by the Fusing Roller Ther-
mistor remains lower than 120°C (105°C for the model
having two Fusing Roller Heater Lamps) for a given
period of time during a print cycle.
• The temperature detected by the Fusing Roller Sub
Thermistor remains lower than 105°C for a given period
of time during the standby state.
• The temperature detected by the Fusing Roller Sub
Thermistor remains lower than 105°C for a given period
of time during a print cycle.
• The temperature detected by the Fusing Roller Ther-
mistor remains higher than 240°C for a given period of
time.
3-17
TROUBLESHOOTING
35 sec.
25 sec.
20 sec.
4 sec.
2 sec.
1 sec.
0.5 sec.
7 sec.
2 sec.
1 sec.
0.5 sec.

Advertisement