MAINTENANCE
(5)
Removal of the PC Drum Charge Corona Assy
3
(6)
Removal of the Cleaning Blade
1. Remove the PC Drum Charge Corona Assy.
(7)
Cleaning of the PC Drum Paper Separator Fingers
1. Remove the PC Drum.
2. Remove the Main Erase.
3. Turn the holder in the rear in the direction of the
4
arrow to remove it from the side bracket.
4. Slide out the PC Drum Charge Corona in the
direction of the arrow.
4035D031AB
2. Remove three screws and the Cleaning Blade.
NOTES
• When securing the Cleaning Blade, tighten screws
in the order of one on one edge, one at the center,
and one on the other edge.
• When the Cleaning Blade has been replaced,
apply a coat of toner to the surface of the PC
Drum.
☞ 1-21
4035D032AA
1. Using a soft cloth dampened with alcohol, wipe
the five Paper Separator Fingers clean of dirt.
4035D033AA
1-18