Vg Adjust; Fuser Temp. Ad (Plain) - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

ADJUSTING/SETTING
(5)

VG ADJUST

Purpose
To adjust image density by varying Vg with
changing sensitivities as the PC Drum is used for
an extended period of time.
✽ When image problems (fog, void) occur
✽ When the PC Drum Unit has been replaced
(6)

FUSER TEMP. Ad (PLAIN)

Purpose
To set the temperature of the Fusing Roller for
each type of paper, thereby making up for fusing
performance that changes with the operating
environment or type of paper.
✽ When fusing failure occurs
✽ When the type of paper is changed
<Temperature table for adjusting fusing temperature for plain paper>
For Di1611
Setting value
251 mm or more
2
250 mm or less
251 mm or more
1
250 mm or less
251 mm or more
0
(default value)
250 mm or less
251 mm or more
-1
250 mm or less
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Paper width
CD
FD
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
2-23
Setting Details/Precautions
• The default setting is "0."
Increase the setting value to eliminate
void.
Decrease the setting value to eliminate
fog.
Setting range: -2 to +2
Setting Details/Precautions
• The default setting is "0."
Setting range: -1 to +2
Mode selected in Service's Choice
Mode 1
Heater Lamp temperature
200 ° C
200 ° C
200 ° C
200 ° C
200 ° C
190 ° C
190 ° C
190 ° C
180 ° C
180 ° C
180 ° C
170 ° C
Mode 3
190 ° C
190 ° C
185 ° C
180 ° C
180 ° C
175 ° C
170 ° C
170 ° C
165 ° C
160 ° C
160 ° C
155 ° C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di2011

Table of Contents