Resetting Procedure By Malfunction Code - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

TROUBLESHOOTING
3.2

Resetting Procedure by Malfunction Code

Code
C0000 Main Motor malfunction
C0044 ADF Cooling Fan Failure
C0045 Fusing Cooling Fan Motor malfunction
Power Supply Cooling Fan Motor mal-
C004E
function
C0070 Toner Replenishing Motor malfunction
C0210 Abnormal image transfer voltage
C03FF Faulty Model Setting
C0500 Warm-up failure
C0501 Warm-up failure 2
Fusing failure (abnormally low fusing
C0510
temperature)
Fusing failure (abnormally low fusing
C0511
temperature 2)
Fusing failure (abnormally high fusing
C0520
temperature)
Fusing failure (abnormally high fusing
C0521
temperature 2)
C0650 Faulty Scanner Home Position Sensor • Turn OFF and ON the Power Switch.
C0B60 Bin Switching Motor malfunction
C0B80 Shift Motor malfunction
C0F32 Faulty ATDC Sensor
C0F33 Improperly adjusted ATDC Sensor
C1038 Engine connection failure
C1200 Faulty ASIC/memory
C1300 Polygon Motor malfunction
C133B Communication with option error
C133D ROM check error
C13F0 Faulty HSYNC
C1468 Faulty EEPROM
C14A3 IR fluorescent lamp fault
Description
3-20
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Procedure
• Turn OFF and ON the Power Switch.
• Make the correct setting for "Model
Setting" of "Adjust" available from the
Service mode.
☞ 2-39
• Turn ON the Power Switch with the
Stop key held down.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di2011

Table of Contents