C133B Communication With Option Error C133D Rom Check Error; (14) C1468 Faulty Eeprom - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
(13) C133B Communication with Option Error
C133D ROM Check Error
<Detection Timing>
Trouble
Code
• It is not possible to communicate with the Printer Board within a pre-
C133B
determined period of time during a print cycle.
• An error is detected of the flash ROM chip on the Fax Board when the
C133D
Power Switch is turned ON.
✽ For detailed corrective action, see the Service Manual for Fax.

(14) C1468 Faulty EEPROM

<Detection Timing>
Trouble
Code
EEPROM fault
C1468
• Data cannot be written in EEPROM.
• Data stored in EEPROM is wrong.
<Action>
Master Board (PWB-A)
Step
Operations
1
Turn OFF the Power Switch and
unplug the power cord. Then, plug in
the power cord and turn ON the
Power Switch again.
2
Check EEPROM (U16) on PWB-C/C
for proper connection and correct as
necessary.
3
Change PWB-A.
4
Change EEPROM.
Description
Description
Relevant Electrical Components
EEPROM (U16)
Ref.
Page
☞ 1-57
3-35
TROUBLESHOOTING
WIRING DIAGRAM