Misfeed At The Manual Bypass Paper Take-Up Section - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

TROUBLESHOOTING
2.5.2

Misfeed at the Manual Bypass Paper Take-up Section

<Detection Timing>
Type
Manual Bypass
• The leading edge of the paper does not unblock the Synchronizing
paper take-up
Roller Sensor (PC1) even after the lapse of a given period of time
section misfeed
after the Paper Take-up Solenoid/Bypass (SL2) has been energized.
detection
• The Synchronizing Roller Sensor (PC1) is not blocked even after the
lapse of a given period of time after the paper has unblocked the Syn-
Size error
chronizing Roller Sensor (PC1).
detection
• The Synchronizing Roller Sensor (PC1) is blocked before the lapse of
a given period of time.
Paper left at the
• The Paper Set Sensor/Bypass (PC2) is blocked at timing when the
Manual Bypass
Power Switch is turned ON, the cover is opened and closed, or a
paper take-up
paper misfeed or malfunction is reset.
section
<Action>
Synchronizing Roller Sensor (PC1)
Paper Take-up Solenoid/Bypass
Step
Operations
1
Initial checks
2
PC1 sensor check
3
SL2 operation check
4
PC2 sensor check
5
Replace PWB-A
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Description
Relevant Electrical Components
Paper Set Sensor/Bypass (PC2)
Master Board (PWB-A)
Ref. Page
☞ 3-1
☞ 3-2
PWB-A PJ12A-2 (REM)
☞ 3-1
3-8
WIRING DIAGRAM
Control signal
PWB-A PJ17A-3 (ON)
PWB-A PJ12A-5 (ON)
Location
(Electrical
Components)
F-8
F-6
A-2