Replacing A System Processor Module In An Air-Cooled 8335-Gtb System - IBM Power System S822LC Manual

Hide thumbs Also See for Power System S822LC:
Table of Contents

Advertisement

Figure 161. Releasing the system processor module from the tool
Replacing a system processor module in an air-cooled 8335-GTB
system
Learn how to replace a system processor module in the air-cooled IBM Power System S822LC (8335-GTB)
system.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2. Remove dust and debris from the system processor socket area. If dust or debris is present, use the
supplied air pump (part number 45D2645) to clean the system processor socket area.
3. Prepare the system processor module for installation:
a. Remove the replacement processor module from the shipping tray. Using the supplied removal
tool (part number 01AF101), align the beveled corner (A) of the tool over the beveled corner of
the module as shown in Figure 162 on page 143.
b. Lower the tool over the system processor module by ensuring that the two guide pins (C) are
inserted into the alignment holes (B) on each side of the tool as shown in Figure 162 on page 143.
Then, push down on the tool to lock the system processor module into the tool as shown in
Figure 163 on page 143. Do not press the blue release tabs until directed to do so later.