v The cold plate installation carrier has a plastic holder for each cold plate, directly over each cold
plate as shown in Figure 6. The carrier has two extra holders.
v Each plastic holder can pivot up as needed to access the cold plates as shown in Figure 7 on page
7.
v Lift and pinch the plastic holder to remove it from the carrier as shown in Figure 8 on page 7.
Removing the plastic holder makes it easier to attach and release the cold plate from the holder.
v Each plastic holder has two slots to secure the two pins on the top of each cold plate as shown in
Figure 9 on page 8. Slide the holder near to the top of the pins, the pins are narrower at the top.
v The carrier has a hook-and-loop fastener to hold the water hoses as shown in Figure 10 on page 8.
Figure 6. The cold plate installation carrier and the cold plate holders. The installation carrier is a metal frame that fits
over the chassis. A plastic holder supports each cold plate; the holders are located directly over each cold plate.
6
Power Systems: Servicing the IBM Power System S822LC (8335-GTB)