Removing And Replacing A System Processor Module For The 8335-Gtb; Removing A System Processor Module From An Air-Cooled 8335-Gtb System - IBM Power System S822LC Manual

Hide thumbs Also See for Power System S822LC:
Table of Contents

Advertisement

c. From the Downloads list, click Scale-out LC system VPD update tool.
d. Follow the directions that are provided with the tool to update the VPD.
4. Restore the BMC network settings by completing the following steps:
a. Access the BMC GUI from a browser. The user needs Administrator privilege. You can use either
Google Chrome or Mozilla Firefox browsers.
b. Navigate to HMC Management > Console Settings > Change BMC/IPMI Network Settings
c. Set the following values:
IP address
Subnet mask
Gateway
5. Update the BMC firmware.
After you replace a system backplane, you must update the BMC firmware. To download the update,
go to the Fix Central website (www.ibm.com/support/fixcentral/). Follow the instructions provided
with the update.

Removing and replacing a system processor module for the 8335-GTB

Learn how to remove and replace a system processor module in the IBM Power System S822LC
(8335-GTB) system.
Removing a system processor module from an air-cooled 8335-GTB
system
Learn how to remove a system processor module from the air-cooled IBM Power System S822LC
(8335-GTB) system.
Before you begin
Power off the system and place it in the service position. For instructions, see "Preparing the 8335-GTB
system to remove and replace internal parts" on page 195.
About this task
As part of the system processor module replacement, the heat sink is removed. The system can use two
types of thermal interface materials (TIMs); silver with trimmed corners, or gray with square corners.
v When the heat sink is removed from the system processor module, the silver-colored thermal interface
material (TIM) is typically adhered to the heat sink. Unless damaged, the TIM that is adhered to the
heat sink can be reused. If the silver-colored TIM is damaged, do not reuse the removed heat sink.
Before you begin the removal and replacement procedure, ensure that you have a spare TIM and heat
sink, part number 01AF286, on hand.
v If a gray-colored TIM is used and needs replacing, ensure that you have a spare TIM, part number
01AF742, on hand. Alternatively, have a spare TIM and heat sink, part number 01AF286, on hand.
134
Power Systems: Servicing the IBM Power System S822LC (8335-GTB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power system 8335-gtb

Table of Contents