Error Messages - DURKOPP ADLER 581 Operating Instructions Manual

Table of Contents

Advertisement

Error
Meaning
1000
Sewing motor fault
1001
Sewing motor fault
1002
Sewing motor insulation
fault
1004
Sewing motor fault
1005
Sewing motor current feed
fault
174

10.2.2 Error Messages

If an error occurs, the
followed by a four-digit number combination.
Possible cause
• Encoder plug (Sub-D,
• Encoder defective
• Sewing motor plug not
• Incorrect direction of
• Sewing motor blocked
• Encoder cable not
• Encoder defective
symbol appears on the display,
9-pin) not connected or
defective
connected or defective
rotation
connected or defective
Operating Instructions 581 - 02.0 - 05/2019
Troubleshooting
Remedial action
• Check the connection
of the encoder cable
and replace, if
necessary
• Check the connection
of the sewing motor
cable
• Test sewing motor
phases (R = 2.8 Ω,
high impedance to PE)
• Replace encoder
• Replace sewing motor
• Replace control
• Check motor phase
and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Replace encoder
• Check plug assignment
and change, if
necessary
• Check wiring in
machine distributor and
change it, if necessary
• Test motor phases and
check for correct value
• Remove blockage
• Check the encoder
cable and replace, if
necessary
• Replace sewing motor

Hide quick links: