Checking The Lubrication - DURKOPP ADLER 581 Operating Instructions Manual

Table of Contents

Advertisement

Setup
Operating Instructions 581 - 02.0 - 05/2019
2.
Turn the pressure regulator until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure regulator (1) down.

7.14 Checking the lubrication

CAUTION
Risk of environmental damage from oil!
Oil is a pollutant and must not enter the sewage
system or the soil.
Carefully collect up used oil.
Dispose of used oil and oily machine parts in
accordance with the legal regulations.
For topping off the oil reservoir, use only lubricating oil DA 10
or oil of equivalent quality with the following specifications:
• Viscosity at 40 °C:10 mm
• Flash point: 150 °C
You can order the lubricating oil from our sales offices using
the following part numbers.
Container
250 ml
1 l
2 l
5 l
You need to supply the wicks and felts as well as the hook and
the needle bar with a small amount of oil during setup / after an
extended standstill period.
2
/s
Part no.
9047 000011
9047 000012
9047 000013
9047 000014
161