92
5.9.3

Thread mon.

In the sub-item Thread mon. the thread monitor for the needle
thread is set.
Parameters in the Thread mon. sub-item
Icon
Entry
Thread mon. S.p.m. after
To adjust the thread monitor:
1.
Select Machine config in the service menu ( p. 82).
2.
Press the
3.
Press the
button as often as required until Thread mon.
is highlighted on the display.
Fig. 58: Thread mon.
4.
Press the
 7 appears on the display.
5.
Enter the desired value using the arrow buttons.
Meaning
which the
sewing process
is canceled due
to a thread
breaking
button
button.
Operating Instructions 581 - 02.0 - 05/2019
Programming
Possible
Preset value
value range
0-14
7