Programming
Operating Instructions 581 - 02.0 - 05/2019
Output test
NOTICE
Property damage may occur!
Testing an output element can lead to collisions with other
machine elements. There is a risk of breaking
Before switching on each output element, make sure that
this cannot collide with other components.
In the sub-item Output test you can test the individual output
elements.
To perform an output test:
1.
Select Output test.
2.
Press the
3.
Using the arrow buttons, select the desired output element.
 The current status is displayed:
• 0 = Output not activated
• 1 = Output activated
4.
Press the
 The output is switched over.
Functions of the operating elements
Output
Function
Y01
Needle thread trimmer;
on the 581-112 and 581-312, additional hook thread
trimmer
Y02
Hook thread tension
Y03
Fabric clamp
Y04
Spreader