Assigning Interfaces - Siemens SINUMERIK 840D sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Tips
13.4 Integrating PG/PC into the network (NetPro)
13.4.3

Assigning interfaces

Introduction
The interfaces configured in the previous chapter must now be assigned in a device-specific
manner to the available hardware interfaces on the PG/PC.
The following operator input sequence steps detail the assignment of the Ethernet interface.
Operator input sequence steps for assigning an Ethernet interface
1. Select the "Assign" tab.
2. Select "Ethernet interface(1)" in the selection field "Configured interfaces".
3. Select the installed network card "TCP/IP -> Realtek RTL8139/810xF..." in the selection
field "Interface parameterizations in PG/PC" (see figure below).
Figure 13-13 Selecting
4. Click on "Assign" and confirm the subsequent message on processing object properties
with "OK".
228
The assigned interfaces are deleted from the field "Configured interfaces" and these
assigned interfaces are displayed in the field "Assigned" (see figure below).
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
IBN CNC: NCK, PLC, drive

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120