Siemens SINUMERIK 840D sl Commissioning Manual page 114

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

NCK start-up
10.2 System data
Figure 10-1
Key to Fig. above:
T
Lag
T
DP
T
DX
T
:Master time: Offset of the start time for NCK position controller
M
GC: Global Control: Broadcast message for cyclic convergence of the equidistance between
DP master and DP slaves
R: CPU time
Dx: Useful data exchange between the DP master and DP slaves
MSG: Acyclic services (e.g. DP/V1, pass token)
RES: Reserve: "Active pause" until the isochronous (equidistant) cycle has expired
Error response
● Alarm: "380005 PROFIBUS DP: Bus access conflict, type t, counter z"
Cause of errors/error handling
● t = 1
114
Position control cycle offset compared to PROFIBUS DP cycle
:CPU time required by position controller
:DP cycle time: DP cycle time
:Data Exchange Time: Total transfer time for all DP slaves
The position-control cycle offset selected is too small. The cyclic PROFIBUS
communication with the drives was not yet completed with the start of the position
controller.
– Remedy: Increase the position-control cycle offset.
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
IBN CNC: NCK, PLC, drive

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents