8.4

Interface Assignment of the Processing Unit

Power supply of "IN 24 V DC" (pin)
Connector
Name
1
+24V
2
+24V
3
M
4
M
Interface to the Lighting Unit "LAMP" (socket)
Connector
Name
1
+16V
2
LIGHT
3
M
4
M
Interface to Sensor Head "SENSOR" (socket)
Connector
Name
Casing
9
M
10
M
14
20
TxDP
21
TxDN
22
CLK_P
23
CLK_N
24
RxD_P
25
RxD_N
26
M
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
Function
24 V power supply
24 V power supply
Ground
Ground
Function
16.5 V power supply
Pulse to start a light flash (24 V)
Ground
Ground
Function
Screening
+16V
Image data +
Image data -
Image synchronization +
Image synchronization -
Sensor parameter +
Sensor parameter -
Direction
Wire Color
-
red
-
orange
-
black
-
brown
Direction
-
Output
-
-
Direction
-
-
-
-
Input
Input
Output
Output
Output
Output
-
Appendix