Operator Input
Part 2/3: Integration
Here, you specify the path over which signals are sent to the processing unit and
over which path the result string is output.
You will find a detailed description of the possible settings in the online help that
you can call with the "Help" button.
Note
You cannot set every combination of settings for String, Result and Control. If a
combination is not permitted, (for example Text = PROFIBUS DP and Control =
DI/DO), an error message to this effect is displayed in the lower part of the dialog.
Part 3/3: Result & String
Here, you specify whether and how result string or filtered text sections, quality
values, positions etc. are output over the RS-232 port of an Ethernet RS-232
converter or over DP or to a TCP server. You can also specify which text appears
on the display of the processing unit if an error occurs.
In the "Result String" group box, you specify whether all characters of the read
code are output or only a substring (according to the filter settings of ID or
Position). With the "Format string" input box, you can also specify the content and
the format of the string to be output. How to make these settings is described in the
online help that you can call with the "Help" button.
In the "Error messages" group box, you specify which text is output on the display
of the processing unit and over Ethernet or DP if the relevant error occurs. You can
select any string to be output by entering the required text in the relevant input box.