Interface Digital Inputs/Outputs - Siemens SIMATIC Vision Sensor VS 130-2 Manual

Hide thumbs Also See for SIMATIC Vision Sensor VS 130-2:
Table of Contents

Advertisement

8.6.3

Interface Digital Inputs/Outputs

Module-Specific Data
Number of inputs
Number of outputs
Cable length, unshielded
Voltage, Currents, Potentials
Rated voltage load current supply L+
Permitted rated voltage load current supply L+
Current consumption L+
Number of simultaneously controllable inputs
Number of simultaneously controllable outputs
Total current of the outputs
Electrical isolation
Data for Selecting a Sensor
Input voltage
Rated value
For signal "1"
For signal "0"
Input current
with "1" signal
Input signal characteristics
Connection of two-wire BERO
Data for Selecting an Actuator
Output voltage
with "1" signal
Output current
with "1" signal
with "0" signal
Off delay (with resistive load)
from "0" to "1"
Load resistor
Lamp load
Parallel wiring of 2 outputs
Operating frequency:
With resistive load
With inductive load to IEC 947-5-1, DC 13
With lamp load
Limit on inductive cutoff voltage
Short-circuit protection of the output
Operating threshold
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
8
6
10 m
24 V DC
20.4 V to 28.8 V
Dependent on configuration
8
6
Max. 1.5 A with max. 0.5 A/output
No
24 V DC
From 13 to 30 V
-30 V to +5 V
Typically 7 mA
"Trigger" input to IEC61131-2 type 2
Other inputs; IEC61131-2 type 1
Max. 1.5 mA
Min. L+ (-1.3 V)
Rated value: 0.5 A.
Permissible range: 5 mA to 0,5 A
Residual current: max. 0.5 mA
max. 100 µs
max. 48 Ω to 4 KΩ
max. 5 W
No
Max. 100 Hz
Max. 0.5 Hz at 0.5 A
Max. 10 Hz
Typically L+ (-53 V)
Solid-state
Typically 1A
Appendix
8-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic vision sensor vs 130-2vcr

Table of Contents