No.
Signal
Bit-No. as of
Diagnostic
byte 0 (DP)
7
ARCH/MMI
7
Trm. Error
8
DP/PNIO Trm.
7
Error
9
Invalid DP
8
Parameters
10
Cycletime too
9
short
(Note: only
with VS 130-2
up to and
including V1.5)
11
Error Training
10
Code
12
Match
11
Mismatch
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
Value
Description
(PROFINET)
W#16# 5007
The send buffer is full because
the data cannot be sent in an
adequately short time or the
server does not confirm
receipt of the data in good
time
W#16# 5007
The transfer of the last read
result is not yet completed, the
next read result is, however,
already available, or the DP
master or IO controller does
not reply within the handshake
monitoring time (parameter
Connect >Ports >DP >Timeout
on processing unit or within
the time limit parameter in
PROFIBUS DP in Part 1/3:
Ports of the Connections
dialog in the setup support,
parameter Connect >Ports
>PNIO >Timeout on
processing unit or within the
time limit parameter in
PROFINET IO in Part 1/3:
Ports in the "Connections"
dialog in the setup support).
-
The DP settings are not
correct
W#16# 5009
During the first code
processing following a change
from STOP to RUN on the
processing unit, the first
processing iteration could not
be completed within 90% of
the set upper limit of the cycle
time.
W#16#500A
No code was found in the
image during training.
W#16#500B
The trained code cannot be
processed with the match
settings (for example
ID/separator not found)
Diagnostics
Possible
Remedies
Reduce the trigger
frequency or
reduce the amount
of diagnostic data
to be archived.
Process the results
on the server
faster. A high load
on the network to
which the
processing unit is
connected can
also block the
transfer of the
data. If necessary,
check the network
connection.
Reduce the trigger
frequency or
process the results
more quickly.
If necessary,
change the
transmission rate
for the DP
configuration or the
update time for the
PROFINET
configuration.
Correct the DP
settings.
Increase the cycle
time, improved the
image quality, or
restart processing
mode.
Position the code
within the image or
improve the image
quality.
Adapt the match
settings, or train a
suitable code.
7-3