Read Results - Siemens SIMATIC Vision Sensor VS 130-2 Manual

Hide thumbs Also See for SIMATIC Vision Sensor VS 130-2:
Table of Contents

Advertisement

Diagnostics
7.2.3

Read Results

No. Signal
Read Err
1
(<reason>)
Filter error
2
Match error
3
Format error
4
Note
When operating using the setup support, make sure you are familiar with the
comprehensive description in the user interface (User Interface of the Web
Application.).
7-10
Description
The code could not be read in the
processing mode.
Note: You can modify this text in
Connect>String>Messages
>ReadErr
Text for the situation when the
values for "Start position" or "Filter
ID" for the current part do not occur
in the read code.
Note: You can modify this text in
Connect>String>Messages
> FilterErr
The parameter selected in
Connect>String>Filter>Option was
not found in the code being
compared or the string defined
during training does not match the
current string of the code.
Note: You can modify this text in
Connect>String>Messages
> MatchErr
Error in the
Connect>String>Format>String
input box.
Note: You can modify this text in
Connect>String>Messages
> Format Err
Possible Remedies
For possible causes, refer to "Error
Training Code" in the error messages.
1.
Check whether the DMC currently
being read is correct.
2.
Check or correct the selected settings
in Connect>String>Filter>StartPos
and ID.
1.
The code currently being read is
different from the trained code (and is
therefore bad) or the wrong code was
trained.
2.
Check the selected parameter
assignment in
Connect>String>Filter>Option.
Check the selected setting in
Connect>String>Format>String.
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01