Siemens SIMATIC Vision Sensor VS 130-2 Manual page 122

Hide thumbs Also See for SIMATIC Vision Sensor VS 130-2:
Table of Contents

Advertisement

Process Interface
Parameters not Interconnected with the Block (static local data):
Parameter
Declaration Data type Address
X_POSITION
STATIC
Y_POSITION
STATIC
ROT_ANGLE
STATIC
INCLINE
STATIC
CONTRAST_F STATIC
GROWTH_F
STATIC
NONUNIF_F
STATIC
ERR_CORR_F STATIC
QUALITY_F
STATIC
CONTRAST
STATIC
GROWTH
STATIC
NONUNIF
STATIC
ERR_CORR
STATIC
6-24
(instance DB)
INT
34.0
INT
36.0
INT
38.0
INT
40.0
CHAR
42.0
CHAR
43.0
CHAR
44.0
CHAR
45.0
CHAR
46.0
REAL
48.0
REAL
52.0
REAL
56.0
REAL
60.0
Default
Description
setting
0
X coordinates of the code mid
point relative to the image mid
point (normalized to image
size 640*480)
0
Y coordinates of the code mid
point relative to the image mid
point (normalized to image
size 640*480)
0
Roll angle of the code mid
point relative to the image mid
point (normalized to image
size 640*480)
0
View angle (angle between
sensor axis and the surface of
the code field)
' '
Symbol contrast as class
(value valid if not ' ')
' '
Print growth as class (value
valid if not ' ')
' '
Axial non-uniformity as class
(value valid if not ' ')
' '
Unused error correction as
class (value valid if not ' ')
' '
Overall quality as class (value
valid if not ' ')
-1.0e+0
Symbol contrast as absolute
value (value valid if not -
1.0e+0)
-1.0e+0
Print growth as absolute value
(value valid if not -1.0e+0)
-1.0e+0
Axial non-uniformity as
absolute value (value valid if
not -1.0e+0)
-1.0e+0
Unused error correction as
absolute value (value valid if
not -1.0e+0)
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr