Diagnostics
7.2.1

Error Messages

When error messages are generated, the "IN_OP" signal (in operation) is reset and
the SF LED (group error) is lit.
With the exception of the error messages PROFIBUS DP Error and PROFINET IO
Error, you must acknowledge all errors that occur by setting the DISA and the RES
bit of the control byte.
If VS 130-2/VS 130-2vcr is connected to PROFIBUS DP or PROFINET I/O, all
error messages trigger a diagnostic interrupt on the respective DP master or I/O
controller, for which there is a number in the "Bit no. as of Diagnostic Byte 0 (DP)"
or "Value (PROFINET)" column in the following table. How to read out and then
analyze the diagnostic information available on the VS 130-2 is described in Slave
Diagnostics or IO Diagnostics.
No.
Signal
Bit-No. as of
Diagnostic
byte 0 (DP)
1
Invalid sensor 0
2
Sensor not
1
found
3
Disable Sig.
3
Change
4
Error in signal
4
sequence
5
Code corrupt
5
6
TCP/RS232
7
Trm. Error
7-2
Value
Description
(PROFINET)
W#16# 5000
The connected sensor type is
not supported.
W#16# 5001
No sensor connected.
W#16# 5003
DISA changed at an invalid
time (during training)
W#16# 5004
During training, the correct
sequence of applied signals is
not kept to.
W#16# 5005
The code could not be
recreated.
W#16# 5007
The send buffer is full because
the data cannot be sent in an
adequately short time,
Possible
Remedies
Connect a sensor
supported by
VS 130-2/VS 130-
2vcr.
Connect the
sensor to the
processing unit
correctly.
Check the
sequence of
applied signals.
Start the training
again.
Check the
sequence of
applied signals.
Start the training
again.
Run the training
again.
Reduce the trigger
frequency or
process the results
more quickly on
the server. A high
load on the
network to which
the processing unit
is connected can
also block the
transfer of the
data. If necessary,
check the network
connection.