Extended setpoint channel

2.7 Direction of rotation limiting and direction of rotation changeover

2.7
Direction of rotation limiting and direction of rotation changeover
Description
A reverse operation involves a direction reversal. Selecting setpoint inversion p1113[C] can
reverse the direction in the setpoint channel.
Parameter p1110[C] or p1111[C] can be set respectively to prevent input of a negative or
positive setpoint via the setpoint channel. However, the following settings for minimum speed
(p1080) in the setpoint channel are still operative. With the minimum speed, the motor can
turn in a negative direction, although p1110 = 1 is set.
Figure 2-6
Function diagrams (see SINAMICS S120/S150 List Manual)
● 1550 Setpoint channel
● 3040 Direction limitation and direction reversal
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Adjustable parameters
● p1110[C] BI: Block negative direction
● p1111[C] BI: Block positive direction
● p1113[C] BI: Setpoint inversion
Parameterization with STARTER
The "Speed setpoint" parameter screen is selected with the
STARTER commissioning tool: