n_XIST2
Meaning
7
Abort get measured value •
8
Abort absolute value
transmission on
3841
Function not supported
Encoder 2 status word (G2_ZSW)
● See G1_ZSW (table 10-29)
Encoder 2 actual position value 1 (G2_XIST1)
● See G1_XIST1
Encoder 2 actual position value 2 (G2_XIST2)
● See G1_XIST2
Function diagrams (see SINAMICS S120/S150 List Manual)
● 4720 Encoder interface, receive signals, encoders n
● 4730 Encoder interface, send signals, encoders n
● 4735 Find reference mark with equivalent zero mark, encoders n
● 4740 Measuring probe evaluation, measured value memory, encoders n
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Adjustable parameter drive, CU_S parameter is marked
● p0418[0...15] Fine resolution Gx_XIST1
● p0419[0...15] Fine resolution Gx_XIST2
● p0480[0...2] CI: Signal source for encoder control word Gn_STW
● p0488[0...2] Measuring probe 1 input terminal
● p0489[0...2] Measuring probe 2 input terminal
● p0490 Invert measuring probe (CU_S)
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
More than one value requested
No value requested.
•
Requested value not available
•
Parking encoder active
•
Parking drive object active
•
Absolute encoder not available
•
Alarm bit absolute value protocol set
•
–
Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
Possible causes / description
461