Display
C
Below, 6 digit
Information on the keys
Table 12- 8
Keys
Key
Name
ON
OFF
Functions
Parameters The significance of these keys depends on the actual display.
Raise
Lower
BOP20 functions
Table 12- 9
Functions
Name
Backlighting
Changeover active drive
Units
Access level
Parameter filter
Selecting the operating
display
User parameter list
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Meaning
Is light (bright) if at least one parameter was changed and the calculation for consistent data
management has still not been initiated.
Displays, e.g. parameters, indices, faults and alarms.
Power-up the drives for which the command "ON/OFF1" should come from the BOP.
Binector output r0019.0 is set using this key.
Powering-down the drives for which the commands "ON/OFF1", "OFF2" or "OFF3" should come
from the BOP.
The binector outputs r0019.0, .1 and .2 are simultaneously reset when this key is pressed. After
the key has been released, binector outputs r0019.1 and .2 are again set to a "1" signal.
Note:
The effectiveness of these keys can be defined by appropriately parameterizing the BICO (e.g.
using these keys it is possible to simultaneously control all of the existing drives).
The significance of these keys depends on the actual display.
Note:
The effectiveness of this key to acknowledge faults can be defined using the appropriate BiCo
parameterization.
If this key is pressed for 3 s, the "Copy RAM to ROM" function is executed. The "S" displayed on
the BOP disappears.
The keys depend on the current display and are used to either raise or lower values.
The backlighting can be set using p0007 in such a way that it switches itself off automatically
after the set time if no actions are carried out.
From the BOP perspective the active drive is defined using p0008 or using the keys "FN" and
"Arrow up".
The units are not displayed on the BOP.
The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
Using the parameter filter in p0004, the available parameters can be filtered corresponding to
their particular function.
Actual values and setpoints are displayed on the operating display.
The operating display can be set using p0006.
Using the user parameter list in p0013, parameters can be selected for access.
12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)
Meaning
Description
Basic information about the drive system
589