Component
Single Motor Module chassis
Power Module blocksize
Power Module chassis
Note
If an additional encoder is connected to a Motor Module, it is assigned to this drive as
encoder 2 in the automatic configuration.
Figure 12-25 Example of a topology with VSM for booksize and chassis components
Table 12- 15 VSM connection
Component
Active Line Module booksize
Active Line Module (chassis)
Power Modules
Note
The following applies for firmware versions < V2.5:
All of the nodes on a DRIVE-CLiQ line must have the same basic sampling time in p0115[0].
Otherwise the VSM must be connected to a separate DRIVE-CLiQ interface on the Control
Unit.
● Only one final node should ever be connected to free DRIVE-CLiQ ports of components
● If possible, Terminal Modules and Sensor Modules of direct measuring systems should
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
within a DRIVE-CLiQ line (e.g. Motor Modules wired in series),
for example, one Sensor Module or one Terminal Module, without forwarding to additional
components.
not be connected to the DRIVE-CLiQ line of Motor Modules but rather to free DRIVE-
CLiQ ports of the Control Unit.
Basic information about the drive system
12.10 Rules for wiring with DRIVE-CLiQ
Connecting the motor encoder via DRIVE-CLiQ
X402
CUA31: Encoder at X202
CU310: Encoder at X100 or via TM31 at X501
X402
VSM connection
X202
X402
The VSM is not supported.