9.9

Acceptance test and certificate

9.9.1

General information about acceptance

Acceptance test
The machine manufacturer must carry out an acceptance test of the selected Safety
Integrated functions (SI functions) on the machine.
During the acceptance test, all the limit values entered for the enabled SI functions must be
exceeded to check and verify that the functions are working properly.
NOTICE
The acceptance test must only be carried out after the safety functions have been
commissioned and POWER ON reset.
Authorized person, acceptance report
Each SI function must be tested and the results documented and signed in the acceptance
certificate by an authorized person. The acceptance certificate must be stored in the
machine logbook.
Authorized in this sense refers to a person who has the necessary technical training and
knowledge of the safety functions and is authorized by the machine manufacturer to carry
out the test.
Note
• The information and descriptions regarding commissioning must be carefully observed.
• If any parameters are altered by SI functions, the acceptance test must be carried out
• Template for the acceptance certificate
Scope of a complete acceptance test
Documentation
Machine documentation (including the SI functions)
1. Machine description and overview diagram
2. SI functions for each drive
3. Description of safety equipment
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
again and documented in the acceptance certificate.
A printed form is available in this manual as an example/suggestion.