● Jog
● Field bus
● Via the analog inputs of the following exemplary components:
2.3

Jog

Description
This function can be selected via digital inputs or via a field bus (e.g. PROFIBUS). The
setpoint is, therefore, predefined via p1058[D] and p1059[D].
When a jog signal is present, the motor is accelerated to the jog setpoint with the
acceleration ramp of the ramp-function generator (referred to the maximum speed p1082;
see diagram "Function chart: jog 1 and jog 2"). After the jog signal has been deselected, the
motor is decelerated via the set ramp of the ramp-function generator.
CAUTION
The "Jog" function is not PROFIdrive-compliant!
Figure 2-2
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
– Setpoint via PROFIBUS, for example
– e.g. Terminal Board 30 (TB30)
– e.g. Terminal Module 31 (TM31)
– e.g. Terminal Module 41 (TM41)
Function chart: jog and OFF1
Extended setpoint channel
2.3 Jog
47