Bit
Meaning
6
Inhibit regenerating
Note:
If regenerative operation is inhibited and power is fed to the DC link (e.g. by braking the motor), the DC link voltage
increases (F30002).
7
Acknowledge error
Note:
Faults are acknowledged at a 0/1 edge via BI: p2103 or BI: p2104 or BI: p2105.
8...9
Reserved
10
Master control by PLC
Note:
This bit should not be set to "1" until PROFIdrive has returned an appropriate status via E_ZSW1.9 = "1".
11...1
Reserved
5
E_STW1_BM (control word for infeeds, metal industry)
See function diagram [2427].
Table 10- 16 Description of E_STW1_BM (control word for infeeds, metal industry)
Bit
Meaning
0
ON/OFF1
1
OFF2
Note:
Control signal OFF2 is generated by ANDing BI: p0844 and BI: p0845.
2
Reserved
3
Enable operation
4...6
Reserved
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
Remarks
1
Inhibit regenerative operation
Regenerative operation is inhibited.
0
Enable regenerative operation
Regenerative operation is enabled.
0/1
Acknowledge error
-
-
1
Control by PLC
This signal must be set so that the process data
transferred via PROFIdrive are accepted and
become effective.
0
No control by PLC
Process data transferred via PROFIdrive are
rejected - i.e. assumed to be zero.
-
-
Remarks
0/1
ON
Pulse enable possible
0
OFF1
Reduce DC link voltage via ramp (p3566),
followed by pulse inhibit/line contactor open
1
No OFF2
Enable possible
0
OFF2
Immediate pulse suppression and switching on
inhibited
-
-
1
Enable operation
Pulse enable is present
0
Disable operation
Pulse inhibit is present
-
-
BICO
BI: p3533
BI: p2103
-
BI: p0854
-
BICO
BI: p0840
BI: p0844
-
BI: p0852
-