3. SP Mode Tables
3710
[HST Concentration Control: Set]
001 Control Method: Selection
3711
[HST Concentration Control: K]
001 Vcnt
002 Vt
003 Sensitivity: HL
004 Sensitivity: HM
005 Sensitivity: ML
006 Set Detection
007 Without Developer
008 With Developer
009 Serial Number 1
010 Serial Number 2
011 Adjustment: Vt
012 Adjustment: Vtref
013 Adjustment: Vtcnt
014 Adjustment: Gamma
224
Sets the select mode if control is done or not
with HST memory.
*ENG
[0 or 1 / 1 / 1/step]
0:NotUse, 1:Use
*ENG
Displays release check value stored in HST
memory.
*ENG
[0.0 to 5.0 / - / 0.1V/step]
Displays release check value stored in HST
memory.
*ENG
[1.22 to 3.77 / - / 0.01V/step]
*ENG
Displays release check value stored in HST
memory.
*ENG
[0.00 to 2.55 / - / 0.01V/step]
*ENG
Displays release check value stored in HST
memory.
*ENG
[0.0 to 5.0 / - / 0.1V/step]
*ENG
*ENG
Displays release check value stored in HST
memory.
*ENG
[0 to 255 / - / 1/step]
*ENG
Displays adjustment value stored in HST
memory.
*ENG
[0.0 to 5.0 / - / 0.1V/step]
Displays adjustment value stored in HST
memory.
*ENG
[0.00 to 5.00 / - / 0.01V/step]
Displays adjustment value stored in HST
memory.
*ENG
[0.0 to 2.55 / - / 0.01mg/cm2/-kV/step]