Ricoh Aficio MP C305SP Field Service Manual page 925

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

020 Interval :Set
021 Page Cnt
3321
[Adjusted Vsg]
001 Vsg reg
011 Vsg dif
021 Vsg reg(BW)
031 Vsg dif(BW)
041 Vsg TM(Front)
042 Vsg TM(Center)
043 Vsg TM(Rear)
[Adjusted Ifsg]
3322
Displays the result value of the Vsg adjustment for each sensor.
001 Ifsg
Sets Vsg adjustment execution Page interval
determined during printin or at the end of
printing.
*ENG
Note: Vsg adjustment is executed when process
control or MUSIC requires the execution. (Not
executed by it.)
[0 to 2000 / 500 / 1page/step]
Displays Page counter used Vsg execution
determination.
*ENG
[0 to 2000 / 0 / 1page/step]
Displays normal reflection light output from
bared belt with Vsg adjustment.
*ENG
[0.00 to 5.50 / - / 0.01V/step]
Displays diffused reflection light output from
bared belt with Vsg adjustment.
*ENG
[0.00 to 5.50 / - / 0.01V/step]
Displays normal reflection light output from
bared belt with Vsg adjustment.
*ENG
[0.00 to 5.50 / - / 0.01V/step]
Displays diffused reflection light output from
bared belt with Vsg adjustment.
*ENG
[0.00 to 5.50 / - / 0.01V/step]
*ENG
Displays normal reflection light output from
bared belt with Vsg adjustment (TM_Front,
*ENG
TM_Center or TM_Rear sensor).
[0.00 to 5.50 / - / 0.01V/step]
*ENG
Displays Vsg adjusted ID sensor LED current.
*ENG
[0.0 to 50.0 / - / 0.1mA/step]