Ricoh Aficio MP C305SP Field Service Manual page 1287

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

[Temperature: Display]
2241
Displays the environment temperature.
004 PCU Temprature
005 Correction Coefficient A
006 Correction Coefficient B
[TS Operation Env. Log]
2242
Displays the rotation of PCU for each temperature.
001 TS<=40
002 40<TS<=45
003 45<TS
004 Log Clear
[Environmental Correction:Trans]
2302
Environmental Correction: Image Transfer Belt Unit
002 Forced Setting
003 Absolute Humidity:Threshold 1
ENG
[0.0 to 70.0 / - / 0.1deg/step]
*ENG
[0.0 to 10.0 / 1 / 0.1/step]
*ENG
[-70.0 to 70.0 / - / 0.1/step]
ENG
ENG
[0 to 99999999 / - / 1 mm/step]
ENG
[- / - / -]
ENG
[Execute]
Sets the environment condition manually.
[0 to 6 / 0 / 1/step]
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
*ENG
3: MM (Middle temperature/ Middle
humidity)
4: MH (Middle temperature/ High
humidity)
5: HH (High temperature/ High humidity)
Adjusts the threshold value between LL and
ML.
*ENG
[0.00 to 100.00 / 4.50 / 0.01g/m
step]
Main SP Tables-2
3
/
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c305spf