Main Sp Tables-2; Sp2-Xxx (Drum) - Ricoh Aficio MP C305SP Field Service Manual

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

3. SP Mode Tables

Main SP Tables-2

SP2-XXX (Drum)

[Charge DC Voltage]
2005
Adjusts the DC component of the charge roller bias in the print modes.
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
[Charge AC Voltage]
2006
Adjusts the AC component of the charge roller bias in the print modes.
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
[Charge AC Current: LL]
2007
Displays/sets the AC current target of the charge roller for LL environment (Low
temperature and Low humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
66
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]