3. SP Mode Tables
111 Rev_Fix:K
112 Rev_Fix:C
113 Rev_Fix:M
114 Rev_Fix:Y
121 N Delay:StdSpd
123 N Delay:LowSpd
3461
[TonerSupply :DANC]
001 PI:Power
011 PI:I Gain
012 PI:P Gain
021 PI:I Limits:Up
022 PI:P Limits:Up
023 PI:I Limits:Low
024 PI:P Limits:Low
031 AW:AWIlow
033 AW:AWIpni
103 PI:SpdCoef:LowSpd
111 SMITH:Gain
202
*ENG
Sets the inverse of transfer rate to make up for
*ENG
the reverse transfer of ANC.
*ENG
[1.000 to 1.500 / 1.000 / 0.001/step]
*ENG
*ENG
Sets the delay time with the number of control
samplings from entrance of toner supply of the
Smith model to sensor.
*ENG
[0 to 200 / 3 / 1/step]
Changes the request values of PI at one time.
*ENG
[5 to 200 / 100 / 1%/step]
Sets I gain.
*ENG
[0.00000 to 0.10000 / 0.01000 /
0.00001/step]
Sets P gain.
*ENG
[0.00000 to 1.00000 / 0.01000 /
0.00001/step]
*ENG
Sets the limit for the I or P request value (supply
plus side).
*ENG
[0.00 to 1.00 / 0.10 / 0.01/step]
Sets the limit for the I request value (supply
minus side).
*ENG
[0.00 to 1.00 / 0.20 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.10 / 0.01/step]
*ENG
Sets AW gain.
[0 to 1000 / 1000 / 1/step]
*ENG
*ENG
[0.01 to 1.00 / 0.50 / 0.01/step]
Sets the gain for the Smith model.
*ENG
[0.00 to 2.00 / 1.00 / 0.01/step]