Ricoh Aficio MP C305SP Field Service Manual page 1463

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

end data set
Specifies the end setting for the summer time mode.
004
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
5401
[Access Control]
103 Default Document ACL
104 Authentication Time
162 ExtAuth Detail
200 SDK1 UniqueID
201 SDK1 Certification Method
210 SDK2 UniqueID
211 SDK2 Certification Method
220 SDK3 UniqueID
221 SDK3 Certification Method
[0 to 0xffffffff / - / 1hex/step]
(Default)
NA: 0x11100200
*CTL
EUR: 0x10500100
ASIA: 0x03100000
Other: 0x00000000
[0 to 3 / 0 / 1/step]
0: Read Only
*CTL
1: Edit
2: Edit/Delete
3: Full control
*CTL
[0 to 255 / 0 / 1sec/step]
*CTL
[ - / 0x00 / 0x01/step]
*CTL
[0 to 0xffffffff / 0 / 1/step]
*CTL
[0 to 0xff / 0 / 1/step]
*CTL
[0 to 0xffffffff / 0 / 1/step]
*CTL
[0 to 0xff / 0 / 1/step ]
*CTL
[0 to 0xffffffff / 0 / 1/step]
*CTL
[0 to 0xff / 0 / 1/step]
Main SP Tables-5
279

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c305spf