Ricoh Aficio MP C305SP Field Service Manual page 936

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

3. SP Mode Tables
001 ALL
002 ProCon
003 MUSIC
004 Init TD Sensor
3501
[Toner End Prohibition Setting]
001 Process Control
002 MUSIC
003 TC Adj.
3510
[ImgQltyAdj :ExeFlag]
001 Toner Recovery: K
002 Toner Recovery: C
003 Toner Recovery: M
004 Toner Recovery: Y
011 Init TD Sensor :K
012 Init TD Sensor :C
013 Init TD Sensor :M
014 Init TD Sensor :Y
021 Process Control
022 Developer Agitating
023 Blade Damage Prevention
200
*ENG
Sets to off for the execution determination of all
image processing adjustments, potential
*ENG
controls, MUSIC condition adjustments, or TD
sensor initial settings.
*ENG
[0 or 1 / 1 / 1/step]
*ENG
0:OFF, 1:ON
*ENG
[0 or 1 / 1 / 1/step]
*ENG
0:Permit, 1:Forbid
*ENG
*ENG
*ENG
Sets the execution flag for toner recovery.
[0 or 1 / 0 / 1/step]
*ENG
*ENG
*ENG
Sets the execution flag for TD sensor initial
*ENG
settings.
*ENG
[0 or 1 / 0 / 1/step]
*ENG
Sets the execution flag for process control.
*ENG
[0 to 2 / 0 / 1/step]
Sets the execution flag for developer agitating.
*ENG
[0 or 1 / 0 / 1/step]
Sets the execution flag for blade damage
prevention mode.
*ENG
[0 or 1 / 0 / 1/step]