Ricoh Aficio MP C305SP Field Service Manual page 484

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

5. System Maintenance
002 Switch to Print
003 Total Counter
5851
[Bluetooth]
Mode
001
Sets the operation mode for the Bluetooth Unit. Press either key. [0:Public][1:Private]
[Remote ROM Update]
5856
Allows the technician to upgrade the firmware using a local port (IEEE1284) when
updating the remote ROM.
002 Local Port
5857
[Save Debug Log]
On/Off (1:ON 0:OFF)
Switches the debug log feature on and off. The debug log cannot be captured until this
001
feature is switched on.
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Target (2: HDD 3: SD)
Selects the storage device to save debug logs information when the conditions set with
002
SP5-858 are satisfied.
[1 to 3 / 2 / 1 /step]
1: IC card, 2: HDD, 3: SD card
482
Determines whether the installation date is
printed on the printout for the total counter.
[0 or 1 / 1 / - ]
0: OFF (No Print)
1: ON (Print)
Displays the total counter at set the setting
day (SP5849-001).
[0 to 99999999 / 0 / 1/step]
*CTL
[0 or 1 / 0 / 1/step]
*CTL
0: Disable
1: Enable
*CTL