Ricoh Aficio MP C305SP Field Service Manual page 1373

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

021 High Coverage Coeff:K
022 High Coverage Coeff:C
023 High Coverage Coeff:M
024 High Coverage Coeff:Y
040 Initial ProCon Thresh
041 High Coverage Thresh:H
050 ProCon Thresh
060 Low Coverage Thresh
070 TC Upper Limit Correction
071 TC Upper Limit:Display:Bk
072 TC Upper Limit:Display:C
073 TC Upper Limit:Display:M
074 TC Upper Limit:Display:Y
3234
[Vtref Corr :Disp/Set]
*ENG
Sets the coefficient Vtref to determine the Vtref
*ENG
correction value with high image coverage.
*ENG
[0.0 to 5.0 / 0.4 / 0.1/step]
*ENG
Sets process control flag and executes process
control by determining the high image
coverage is successive if the cumulative
*ENG
average (M) of image coverage (SP3224-009
to 012) is more than the specified value.
[0 to 255 / 6 / 1times/step]
This SP is referenced when an output of high
image coverage.
*ENG
[0 to 100 / 60 / 1%/step]
*ENG
[0 to 255 / 14 / 1times/step]
This SP is referenced when an output of low
image coverage.
*ENG
[0.0 to 20.0 / 3.0 / 0.1%/step]
Sets Vtref lower limit (TC upper limit) which can
be canceled temporarily by determining the
low image coverage is successive if the
cumulative average (L) of image coverage
*ENG
(SP3224-013 to 016) is less than the specified
value.
[0.0 to 5.0 / 0.5 / 0.1wt%/step]
*ENG
Displays Vtref lower limit (TC upper limit) which
can be canceled temporarily by determining
*ENG
the low image coverage is successive if the
cumulative average (L) of image coverage
*ENG
(SP3224-013 to 016) is less than the specified
value.
*ENG
[1.0 to 15.0 / - / 0.1wt%/step]
Main SP Tables-3
189

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c305spf

Table of Contents