3. SP Mode Tables
142 Postcard:Thick1:FC:Press
145 Postcard:Thick2:FC:Center
146 Postcard:Thick2:FC:Press
149 Postcard:Thick3:FC:Center
150 Postcard:Thick3:FC:Press
[Fusing Temp. Display] Fusing Temperature Display (Heating or Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Center
End
002
The heating roller has two lamps. One heats the center of the heating roller and the other
heats both ends of the heating roller.
Pressure: Center
003
The pressure roller has two lamps. One heats the center of the heating roller and the
other heats both ends of the heating roller.
004 Pressure: End
005 Fusing Roller: End
1107
[Standby Target Temp. Setting]
Stanby/Preheat1:Center
001
Specifies the time that the fusing heater turns off after the fusing unit temperature has
reached its target temperature.
Preheat2:Center
003
Specifies the temperature of the heating roller for the ready or energy save 2 mode.
Low Power:Center
005
Specifies the temperature of the heating roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
26
*ENG
[0 to 200 / 150 / 1deg/step]
*ENG
[100 to 180 / 145 / 1deg/step]
*ENG
[0 to 200 / 150 / 1deg/step]
*ENG
[100 to 180 / 150 / 1deg/step]
*ENG
[0 to 200 / 150 / 1deg/step]
*ENG
[-50 to 250 / - / 1deg/step]
*ENG
[-20 to 348 / - / 1deg/step]
*ENG
[-20 to 250 / - / 1deg/step]
*ENG
[-20 to 250 / - / 1deg/step]
*ENG
[-20 to 250 / - / 1deg/step]
*ENG
[0 to 100 / 60 / 1deg/step]
*ENG
[-50 to 100 / 60 / 1deg/step]
*ENG
[-50 to 100 / -50 / 1deg/step]
*ENG
[0 to 180 / 150 / 1deg/step]