3. SP Mode Tables
021 Fusing Pad
022 ZnSt: PCU:K
023 ZnSt: PCU:C
024 ZnSt: PCU:M
025 ZnSt:PCU:Y
026 ZnSt:Image Transfer Unit
027 Toner Sub Hopper: K
028 Toner Sub Hopper: C
029 Toner Sub Hopper: M
030 Toner Sub Hopper: Y
3710
[HST Concentration Control: Set]
001 Control Method: Selection
3711
[HST Concentration Control: K]
001 Vcnt
002 Vt
003 Sensitivity: HL
228
Sets the flag for new fusing pad manual
settings.
*ENG
[0 or 1 / 0 / 1/step]
*ENG
Sets the flag for new lubricant for PCU manual
*ENG
settings.
*ENG
[0 or 1 / 0 / 1/step]
*ENG
Sets the flag for new lubricant for image
transfer unit manual settings.
*ENG
[0 or 1 / 0 / 1/step]
*ENG
Sets the flag for new toner sub hopper manual
*ENG
settings.
*ENG
[0 or 1 / 0 / 1/step]
*ENG
Sets the select mode if control is done or not
with HST memory.
*ENG
[0 or 1 / 1 / 1/step]
0:NotUse, 1:Use
*ENG
Displays release check value stored in HST
memory.
*ENG
[0.0 to 5.0 / - / 0.1V/step]
Displays release check value stored in HST
memory.
*ENG
[1.22 to 3.77 / - / 0.01V/step]