Ricoh Aficio MP C305SP Field Service Manual page 951

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

041 Low Speed Slope:K
042 Low Speed Slope:C
043 Low Speed Slope:M
044 Low Speed Slope:Y
051 Low Speed intercept:K
052 Low Speed intercept:C
053 Low Speed intercept:M
054 Low Speed intercept:Y
3624
[TC Adj. Mode]
001 Target(Upp Limit)
002 Target(Lwr Limit)
005 Force Consume Threshhold
006 Consume(Upp Limit)
007 Consume(Upp Limit)
*ENG
*ENG
[-1000 to 1000 / 128 / 1/step]
*ENG
*ENG
*ENG
*ENG
[-1000 to 1000 / 7 / 1/step]
*ENG
*ENG
Sets the upper limit of the target range of
developer gamma adjustment for toner density
adjustment process control.
*ENG
[0.00 to 1.00 / 0.15 / 0.01mg/cm2/-kV/
step]
Sets the lower limit of the target range of
developer gamma adjustment for toner density
adjustment process control.
*ENG
[0.00 to 1.00 / -0.15 / 0.01mg/cm2/-kV/
step]
Sets the forced consumption threshold for toner
density adjustment process control.
*ENG
[1.00 to 6.00 / 1.50 / 0.01mg/cm2/-kV/
step]
Sets the consumptin pattern for toner density
adjustment process control.
*ENG
[10 to 2550 / 127 / 10cm^2/step]
Sets the upper limit of number of consumptions
for toner density adjustment process control.
*ENG
[0 to 255 / 17 / 1times/step]
Main SP Tables-3