Ricoh Aficio MP C305SP Field Service Manual page 1284

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

3. SP Mode Tables
Page: Stand-By: BW
Adjusts the threshold of the line position adjustment for BW printing mode in stand-by
006
mode. The line position adjustment is done when the number of outputs in BW printing
mode reaches the value specified with this SP and the condition of SP2-193-008 or
SP2-193-009 is satisfied
Page: Stand-By: FC
Adjusts the threshold of the line position adjustment for BW printing mode in stand-by
007
mode. The line position adjustment is done when the number of outputs in color printing
mode reaches the value specified with this SP and the condition of SP2-193-008 or
SP2-193-009 is satisfied.
Temp.
Adjust the temperature change threshold for the line position adjustment (Mode b:
008
adjustment once). The timing for line position adjustment depends on the combinations of
several conditions.
Time
009
Adjust the time threshold for the line position adjustment (Mode b: adjustment once). The
timing for line position adjustment depends on the combinations of several conditions.
Magnification
010
Adjusts the magnification threshold for line position adjustment. If the length of the main
scan is changed by this amount since the previous MUSIC, then MUSIC is done again.
Temp. 2
Adjust the temperature change threshold for the line position adjustment (Mode a:
011
adjustment twice). The timing for line position adjustment depends on the combinations of
several conditions.
Time 2
012
Adjust the time threshold for the line position adjustment (Mode a: adjustment twice). The
timing for line position adjustment depends on the combinations of several conditions.
013 Temp. 3
016 Page: Power ON:BW+FC
100
*ENG
[0 to 999 / 100 / 1page/step]
*ENG
[0 to 999 / 100 / 1page/step]
*ENG
[0 to 100 / 5 / 1deg/step]
*ENG
[1 to 1440 / 300 / 1minute/step]
*ENG
[0.00 to 1.00 / 0.10 / 0.01%/step]
*ENG
[0 to 100 / 10 / 1deg/step]
*ENG
[1 to 9999 / 600 / 1minute/step]
*ENG
[0 to 100 / 100 / 1deg/step]
*ENG
[0 to 999 / 200 / 1page/step]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c305spf

Table of Contents