[Fan Control Off Mode Time Set]
1952
Specifies the time for fan control off mode.
001 Fan Control Off Mode Time Set
[Extra Fan Control]
1953
Configures the settings of extra fan control.
001 Cancellation Temp. Threshold
006 Execution Temp. Threshold
007 Cancellation Temp. Threshold
fan setting with or without
008
operation
[Fan Medium Speed Control]
1954
Fan low noise mode end temperature
001 Fan Low Noise Mode End Temp.
*ENG
[0 to 60 / 10 / 1min/step]
*ENG
[0 or 1 / 0 / 1/step]
*ENG
[0.0 to 100.0 / 42.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 5.0 / 0.1deg/step]
*ENG
[0 or 1 / - / 1/step]
*ENG
[0.0 to 100.0 / 30.0 / 0.1deg/step]